44 research outputs found

    Biodiversity conservation: history, protected areas and hotspots

    Get PDF
    Angola is a large country of great physiographic, climatic and habitat diversity, with a corresponding richness in animal and plant species. Legally protected areas (National Parks and Game Reserves) were established from the 1930s and occupied 6% of the country’s terrestrial area at the time of independence in 1975. As a consequence of an extended war, the Protected Areas were exposed to serious neglect, poaching and land invasions. Many habitats of biogeographic importance, and many rare and endemic species came under threat. The recently strengthened administration gives cause for optimism that a new era for biodiversity conservation is at hand. The Protected Areas system was greatly expanded in 2011, and increasing resources are being made available towards achieving management effectivenessinfo:eu-repo/semantics/publishedVersio

    Measurement of D s <sup>±</sup> production asymmetry in pp collisions at √s=7 and 8 TeV

    Get PDF
    The inclusive Ds±D_s^{\pm} production asymmetry is measured in pppp collisions collected by the LHCb experiment at centre-of-mass energies of s=7\sqrt{s} =7 and 8 TeV. Promptly produced Ds±D_s^{\pm} mesons are used, which decay as Ds±ϕπ±D_s^{\pm}\to\phi\pi^{\pm}, with ϕK+K\phi\to K^+K^-. The measurement is performed in bins of transverse momentum, pTp_{\rm T}, and rapidity, yy, covering the range 2.5<pT<25.02.5<p_{\rm T}<25.0 GeV/c/c and 2.0<y<4.52.0<y<4.5. No kinematic dependence is observed. Evidence of nonzero Ds±D_s^{\pm} production asymmetry is found with a significance of 3.3 standard deviations.Comment: All figures and tables, along with any supplementary material and additional information, are available at https://cern.ch/lhcbproject/Publications/p/LHCb-PAPER-2018-010.htm

    Search for CP violation in Λb0→pK− and Λb0→pπ− decays

    Get PDF
    A search for CP violation in Λb0→pK− and Λb0→pπ− decays is presented using a sample of pp collisions collected with the LHCb detector and corresponding to an integrated luminosity of 3.0fb−1. The CP -violating asymmetries are measured to be ACPpK−=−0.020±0.013±0.019 and ACPpπ−=−0.035±0.017±0.020, and their difference ACPpK−−ACPpπ−=0.014±0.022±0.010, where the first uncertainties are statistical and the second systematic. These are the most precise measurements of such asymmetries to date

    Search for dark photons produced in 13 TeV pppp collisions

    Get PDF
    Searches are performed for both promptlike and long-lived dark photons, A 0 , produced in proton-proton collisions at a center-of-mass energy of 13 TeV, using A 0 → μ þ μ − decays and a data sample corresponding to an integrated luminosity of 1 . 6 fb − 1 collected with the LHCb detector. The promptlike A 0 search covers the mass range from near the dimuon threshold up to 70 GeV, while the long-lived A 0 search is restricted to the low-mass region 214 <m ð A 0 Þ < 350 MeV. No evidence for a signal is found, and 90% confidence level exclusion limits are placed on the γ – A 0 kinetic-mixing strength. The constraints placed on promptlike dark photons are the most stringent to date for the mass range 10 . 6 <m ð A 0 Þ < 70 GeV, and are comparable to the best existing limits for m ð A 0 Þ < 0 . 5 GeV. The search for long-lived dark photons is the first to achieve sensitivity using a displaced-vertex signature

    Measurement of CPCP asymmetry in Bs0DsK±B_s^0 \to D_s^{\mp} K^{\pm} decays

    Get PDF
    We report the measurements of the CPCP-violating parameters in Bs0DsK±B_s^0 \to D_s^{\mp} K^{\pm} decays observed in pppp collisions, using a data set corresponding to an integrated luminosity of 3.0fb13.0\,\text{fb}^{-1} recorded with the LHCb detector. We measure Cf=0.73±0.14±0.05C_f = 0.73 \pm 0.14 \pm 0.05, AfΔΓ=0.39±0.28±0.15A^{\Delta \Gamma}_f = 0.39 \pm 0.28 \pm 0.15, AfΔΓ=0.31±0.28±0.15A^{\Delta \Gamma}_{\overline{f}} = 0.31 \pm 0.28 \pm 0.15, Sf=0.52±0.20±0.07S_f = -0.52 \pm 0.20 \pm 0.07, Sf=0.49±0.20±0.07S_{\overline{f}} = -0.49 \pm 0.20 \pm 0.07, where the uncertainties are statistical and systematic, respectively. These parameters are used together with the world-average value of the Bs0B_s^0 mixing phase, 2βs-2\beta_s, to obtain a measurement of the CKM angle γ\gamma from Bs0DsK±B_s^0 \to D_s^{\mp} K^{\pm} decays, yielding \gamma = (128\,_{-22}^{+17})^\circ modulo 180180^\circ, where the uncertainty contains both statistical and systematic contributions. This corresponds to 3.8σ3.8\,\sigma evidence for CPCP violation in the interference between decay and decay after mixing.We report the measurements of the CP -violating parameters in Bs0_{s}^{0}  → Ds_{s}^{∓} K±^{±} decays observed in pp collisions, using a data set corresponding to an integrated luminosity of 3.0 fb1^{−1} recorded with the LHCb detector. We measure Cf_{f} = 0.73 ± 0.14 ± 0.05, AfΔΓ_{f}^{ΔΓ}  = 0.39 ± 0.28 ± 0.15, AfΔΓ=0.31±0.28±0.15 {A}_{\overline{f}}^{\varDelta \varGamma }=0.31\pm 0.28\pm 0.15 , Sf_{f} = −0.52 ± 0.20 ± 0.07, Sf=0.49±0.20±0.07 {S}_{\overline{f}}=-0.49\pm 0.20\pm 0.07 , where the uncertainties are statistical and systematic, respectively. These parameters are used together with the world-average value of the Bs0_{s}^{0} mixing phase, −2βs_{s} , to obtain a measurement of the CKM angle γ from Bs0_{s}^{0}  → Ds_{s}^{∓} K±^{±} decays, yielding γ = (12822+17_{− 22}^{+ 17} )° modulo 180°, where the uncertainty contains both statistical and systematic contributions. This corresponds to 3.8 σ evidence for CP violation in the interference between decay and decay after mixing

    Measurement of the electron reconstruction efficiency at LHCb

    Get PDF
    The single electron track-reconstruction efficiency is calibrated using a sample corresponding to 1.3 fb−1 of pp collision data recorded with the LHCb detector in 2017. This measurement exploits B+→ J/ψ(e+e−)K+ decays, where one of the electrons is fully reconstructed and paired with the kaon, while the other electron is reconstructed using only the information of the vertex detector. Despite this partial reconstruction, kinematic and geometric constraints allow the B meson mass to be reconstructed and the signal to be well separated from backgrounds. This in turn allows the electron reconstruction efficiency to be measured by matching the partial track segment found in the vertex detector to tracks found by LHCb's regular reconstruction algorithms. The agreement between data and simulation is evaluated, and corrections are derived for simulated electrons in bins of kinematics. These correction factors allow LHCb to measure branching fractions involving single electrons with a systematic uncertainty below 1%

    Otimização de imagens mamográficas Optimization of mammographic images

    No full text
    OBJETIVO: Este trabalho tem como objetivo a otimização de imagens mamográficas, com consideráveis reduções de doses. MATERIAIS E MÉTODOS: Neste estudo o feixe de raios-X foi calibrado para cada tensão (kVp), de modo a determinar a melhor combinação de kVp e mAs que irá proporcionar uma densidade ótica (DO) em torno de 1.0 acima da base mais véu do filme utilizado. RESULTADOS: Serão discutidas questões sobre os métodos empregados para a seleção de parâmetros de exposição do feixe de raios-X, seleção da melhor imagem utilizando o método de avaliação gradativa visual, comparações entre as doses e carga do tubo (kVp × mAs) proporcionadas pelas técnicas determinadas neste estudo e pelas utilizadas na rotina clínica do Serviço de Diagnóstico por Imagem do Hospital das Clínicas da Faculdade de Medicina de Botucatu. Neste estudo foram obtidas imagens radiográficas de mama de excelente qualidade, com redução de dose e carga de tubo, respectivamente, de 36,8% e 46,2%, quando comparadas com a técnica utilizada pela rotina clínica da instituição. CONCLUSÃO: Esta pesquisa vem contribuir com a otimização da relação risco-benefício para o paciente e custo-benefício para a instituição.<br>OBJECTIVE: The aim of this study is the optimization of mammographic images with a considerable radiation dose reduction. MATERIALS AND METHODS: In the present study the X-ray beam was calibrated for each tension (kVp), aiming at determining the best combination between kVp and mAs, resulting in optical densities of about 1.0 above the base-plus-fog density. RESULTS: This study will bring into question the methods for X-ray beam calibration, the choice of the best image by means of visual grading analysis, comparisons between doses and tube load (kVp × mAs) delivered by the techniques described in this study and by those adopted in the clinical routine at Service of Diagnostic Imaging of Faculdade de Medicina de Botucatu Clinics Hospital, Botucatu, SP, Brazil. Excellent breast radiographic images have been obtained with doses and tube loads reduction of respectively 36.8% and 46.2% in comparison to those employed in our institutions' clinical routine. CONCLUSION: This study is a contribution to the optimization of the risk-benefit ratio for patients and cost-benefit ratio for the institution
    corecore